BRC8 Compliant Breakage Kits and Procedures

BRC8 Compliant Breakage Kits and Procedures: Clause 4.9.4.4 “The use of dedicated, clearly identifiable cleaning equipment (e.g. color coded) for removal o


BRC8 Compliant Breakage Kits and Procedures:

Clause 4.9.4.4

“The use of dedicated, clearly identifiable cleaning equipment (e.g. color coded) for removal of contained breakages, such equipment shall be stored separately from other cleaning equipment.”

“The use of dedicated, accessible, lidded waste containers for the collection of damaged containers and fragments.”

 

Amerisan Glass Breakage Kits:

 

K80700G.Glass Breakage Incident Clean Up Kit Green.1Everything needed to deal with glass breakage quickly and efficiently all in one self-contained kit. Includes: 1 lobby pan with:

  • Detachable handle
  • 1 medium bristle hand brush
  • 1 crevice brush
  • 1 blue microfiber cloth
  • Caution tape (300ft)
  • 3 pairs of blue nitrile gloves
  • 1 glass breakage
  • 1 clean-up procedure guide

 

Glass/Brittle Plastic Breakage Procedure:

Using the BRC8 Compliant Kit in the event of a glass or brittle plastic breakage this procedure should be followed:

1. Cease all operations within a 50 ft. radius of the breakage.

2. Cordon off a 65 ft. radius from the breakage.

3. Ensure all contaminated personnel, footwear or clothing remains within the cordoned area.

4. A responsible technical or quality personnel should be called to oversee clean-up.

5. Glass breakage incident kit should be brought to the area.

6. The person(s) responsible for cleaning should put gloves on to avoid cutting themselves.

7. Staff that may be contaminated should remove overalls and have footwear brushed.

8. Staff should be checked before they can leave the area.

9. Using the hand and crevice brush, all fragments of glass / brittle plastic should be swept up and placed inside the lobby pan to contain the breakage. Check-in, on and beside all pieces of equipment.

10. When all glass/brittle plastic has been removed from the area, place all used utensils into the lobby pan and close the lid.

11. Remove used equipment (brushes, cloth, etc.) from the factory. Discard all used items to waste and reorder replacements from Amerisan (kit product code: K80700). (Although some cleaning equipment may be cleaned, the best industry practice is to discard it to avoid potential glass / brittle plastic contamination).

12. The whole cordoned area should be visually checked by a responsible member of the technical or quality team to ensure all fragments of glass / brittle plastic have been removed. Once this is complete and confirmation that all glass / brittle plastic has been removed, production can recommence.

 

For best practice, an incident report should be completed, the clean-down verified, and a small sample of the glass / brittle plastic attached to the incident report and stored. This facilitates examination against any future glass / brittle plastic complaints you might get to ensure contamination was not from the breakage incident.

Available in the 10 Standard Colors, Amerisan provides Liquid, Allergen, Solids, and Glass Clean Up Kits – All BRC8 Compliant!